End Of Support For IBM InfoSphere 9.1.0

IBM Information Server (IIS)
IBM Information Server (IIS)

End of Support for IBM InfoSphere Information Server 9.1.0

IBM InfoSphere Information Server 9.1.0 will reach End of Support on 2018-09-30.  If you are still on the InfoSphere Information Server (IIS) 9.1.0, I hope you have a plan to migrate to an 11-series version soon.  InfoSphere Information Server (IIS) 11.7 would be worth considering if you don’t already own an 11-series license. InfoSphere Information Server (IIS) 11.7 will allow you to take advantage of the evolving thin client tools and other capabilities in the 2018 release pipeline without needing to perform another upgrade.

Related References

IBM Support, End of support notification: InfoSphere Information Server 9.1.0

IBM Support, Software lifecycle, InfoSphere Information Server 9.1.0

IBM Knowledge Center, Home, InfoSphere Information Server 11.7.0, IBM InfoSphere Information Server Version 11.7.0 documentation

How to know if your Oracle Client install is 32 Bit or 64 Bit

Oracle Database, How to know if your Oracle Client install is 32 Bit or 64 Bit
Oracle Database

 

How to know if your Oracle Client install is 32 Bit or 64 Bit

Sometimes you just need to know if your Oracle Client install is 32 bit or 64 bit. But how do you figure that out? Here are two methods you can try.

The first method

Go to the %ORACLE_HOME%\inventory\ContentsXML folder and open the comps.xml file.
Look for <DEP_LIST> on the ~second screen.

If you see this: PLAT=”NT_AMD64” then your Oracle Home is 64 bit
If you see this: PLAT=”NT_X86” then your Oracle Home is 32 bit.

It is possible to have both the 32-bit and the 64-bit Oracle Homes installed.

The second method

This method is a bit faster. Windows has a different lib directory for 32-bit and 64-bit software. If you look under the ORACLE_HOME folder if you see a “lib” AND a “lib32” folder you have a 64 bit Oracle Client. If you see just the “lib” folder you’ve got a 32 bit Oracle Client.

Related References

 

Oracle – How to get a list of user permission grants

IBM Infosphere Information Server (IIS), Oracle – How to get a list of user permission grants
IBM Infosphere Information Server (IIS)

Since the Infosphere, information server, repository, has to be installed manually with the scripts provided in the IBM software, sometimes you run into difficulties. So, here’s a quick script, which I have found useful in the past to identify user permissions for the IAUSER on Oracle database’s to help rundown discrepancies in user permissions.

 

SELECT *

FROM ALL_TAB_PRIVS

WHERE  GRANTEE = ‘iauser’

 

If we cannot run against the ALL_TAB_PRIVS view, then we can try the ALL_TAB_PRIVS view:

 

SELECT *

FROM USER_TAB_PRIVS

WHERE  GRANTEE = ‘iauser’

 

Related References

oracle help Center > Database Reference > ALL_TAB_PRIVS view

InfoSphere DataStage – Operations Manual Template

When projects transition to production, the receiving team need some transition documentation to help with knowledge transfer and to guide them while they get accustomed to operating the application and can form their own documentation.  This temple is a shell, which usually provides enough detail, with some updating, to provide a quick reference regarding the application.  Also, having a temple can be a real time-saver, as opposed to writing it from scratch.

Related References

Infosphere Datastage – Standard Practice- Sequence Naming Conventions

Standard practices help you and other understand your work.  This can be very important when working on large teams, working across team boundaries, or when large complex sets of process and objects may be involved.  When you consider the importance of naming convention, when coupled with standard practice, the benefit should be obvious, but often practice doesn’t execute or document their conventions.  So, these standard naming conventions may help when none exist or you need to assemble your own naming conventions.

<<SomeIdentifier >> = should be replaced with appropriate information

  1. Sequence Object Naming Conventions
EntityConvention
Master Control Sequence (parent)Master_<<Application>>_ <<Application Job Stream Name>>_Seq
Sequence<<Application>>_<<job_Name>>_Seq
  1. Sequence Stage Naming Conventions
EntityConvention
End LoopEL__<<PrimaryFunction>>
Error Handler EH_<<PrimaryFunction>>
Execute CommandEC_<<PrimaryFunction>>
Job Activity Job_<<PrimaryFunction>>
Nested Condition NC_<<PrimaryFunction>>
Notify Notify_<<PrimaryFunction>>
Routine Activity Rtn_<<PrimaryFunction>>
Sequence Links (messages) Msg_<<Number or Description>>
Sequence Links (Non-messages) Lnk_<<Number or Description>>
SequencerSeqr_<<Number or Description>>
Sequencer (All) SeqAll_<<Identifier>>
Sequencer (Any) SeqAny_<<Identifier>>
Start LoopSL__<<PrimaryFunction>>
Terminator ActivityTA__<<PrimaryFunction>>
User VariablesUV__<<PrimaryPurpose>>
Wait For File WFF__<<PrimaryFunction>>

Related References

InfoSphere DataStage – Ways to Create a Datastage Parameter Set

There are three primary ways to create a parameter sets and is a different practice from adding ‘User Defined’ variables in InfoSphere DataStage Administrator. The ways to create a parameter set are:

  • Create a parameter set from a data connection stage
  • Create a Parameter Set from the navigation of DataStage designer, and
  • Create a Parameter Set from a job

Create a parameter set from Data Connection Stage

This is used to create parameter sets for Database connections parameters

To create a new Parameter Set from a Data Connection

  • Select: File > New > Other and select “Data Connection
  • Complete the data Connection stage properties, then save the stage.
  • Open the Connection stage and navigate to the “Parameters” Tab
  • Then, click on the “Associated Parameter Set” button, and Chose the “Create & Attach” menu item
  • This will Launch a Dialog
  • Fill out the appropriate information on the General tab and the proceed to the Parameters Tab:
  • In the Parameters Tab, enter in the Parameters you wish to include in this Parameter Set
  • On the Values tab, specify a Value File name (please follow naming convention standards to prevent rework and other problems). This is the name of the file that will automatically be created on the Engine tier. This tab also allows you to view/edit values located in the value file.
  • Click OK to save the Parameter set.

Create a Parameter Set from the navigation of DataStage designer

This is, perhaps, the more traditional way of creating a parameter set.

To create a new Parameter Set

  • Select: File > New > Other and select “Parameter Set”
  • This will Launch a Dialog
  • Fill out the appropriate information on the General tab and the proceed to the Parameters Tab:
  • In the Parameters Tab, enter in the Parameters you wish to include in this Parameter Set.
Note: Existing Environment Variables can also added.
  • Create a Parameter Set from a job
    On the Values tab, specify a Value File name (please follow naming convention standards to prevent rework and other problems). This is the name of the file that will automatically be created on the Engine tier. This tab also allows you to view/edit values located in the value file.
  • Click OK to save the Parameter set.

This approach is, perhaps, less traditional, but is equally effective, if you find yourself creating additional jobs and now need to share the same parameters.  This is a quick and easy to generate a parameter set from an existing job.

To create a new Parameter Set from a job

  • Open the job that you want to create a parameter set for.
  • Click “Edit > Job Properties” to open the “Job Properties” window.
  • Click the “Parameters” tab.
  • Press and hold the Ctrl key, then select the parameters that you want to include in the parameter set.
  • With your parameters highlighted, click “Create Parameter Set”.  The Parameter Set window opens.
    • Enter a name and short description for your parameter set.
    • Click the “Parameters” tab; the parameters that you selected are listed.
    • Click the ”Values” tab.
    • Enter a name in the Value File name field, then press Enter.  The value for each of your parameters is automatically populated with the path name that you entered.
    • If a default value is not already set, enter a value for each parameter. For example, if the variable is a Pathname type, enter a default path name.
    • Click “OK” to close the Parameter Set window.
    • In the Save Parameter Set As window, select the folder where you want to save your parameter set and click Save. When prompted to replace the selected parameters with the parameter set, click Yes.
  • Click “OK” to close the Job Properties window.

Related References